Click to Share
 

Model 4338-200 2-Channel LVDT AC Excitation Digital Signal Conditioner

CellMite® Model 4338-200 Dual-Channel LVDT AC Excitation Digital Signal Conditioner connects to a standard AC LVDT (Linear Variable Differential Transformer) transducer and generates a serial output for connection to a PC and a +/-10V analog output.

Manufacturer - Electro Standards Laboratories
Model # - 4338-200
SKU - 303338
Submitted By - Electro Standards Laboratories (Manufacturer)
Country - United States
Category - Other : Signal Conditioner : LVDT AC

Contact   |   Link To Product   |   More Products By This Company

Images

Click on an image to see larger size image ...

Model 4338-200 2-Channel LVDT Signal Conditioner

Specifications

Excitation Voltage :   3kHz, 3Vrms (std)
Excitation Sensors :   LVDT's AC Bridges
Internal Resolution :   24-bit
Input Ranges :   Less than 10mV/V to More than 100mV/V
Conversion Rate :   60/sec 1-channel; 7.5/sec 2-channel
Error :   0.05% +/-1 Count
Precision Shunt :   60K ohms for bridge applications
Pushbutton :   Tare, Shunt
Indicator :   Status LED
Analog Output :   16-bit, Scalable, +/-10V
Serial Data :   Multi-drop RS232, RS485
Switch :   Dual Solid State Relays

Details

CellMite® 4338-200 LVDT AC Excitation Dual Channel Intelligent Digital Signal Conditioner

The CellMite® Model 4338-200 Dual Channel LVDT digital signal conditioner connects directly to two standard AC LVDT (Linear Variable Differential Transformer) transducers and simultaneously generates a serial output for connection to a PC and a +/-10V analog output.

The CellMite 4338-200 LVDT can be operated with a computer or simply setup by a computer and then used as a stand-alone intelligent LVDT digital signal conditioner with analog output.

The Model 4338-200 has on board storage for up to 3 calibrated LVDT's, each with integrated 6-point calibration that can be used to linearize the LVDT outputs. Its multidrop RS232/RS485 serial port and simple command set allow for connection of multiple units in a serial network configuration. This compact unit is ideally suited for in-situ transducer conditioning and distributed process measurements.

Model 4338-200 features include non-volatile memory for parameter and calibration storage, the ability to select between 3 stored LVDT calibrations, and automatic LVDT indentification using TEDS-Tag® technology. Solid state relay switches, multi-point and mV/V calibration, and the ability to locate LVDT core null position are incorporated into the unit. Internal generation of precision sine wave AC excitation voltages, remote sense excitation, and 24-bit internal resolution with 16-bit analog output are also standard.

CellMite® 4338-200 Features:

Dual Channel
2-pt, mV/V Calibration
6-pt Linearization Calibration
Scalable +/-10V Analog Output
16-Bit Analog Output
Direct to PC with RS232 Data
Internal 24-Bit Resolution
Multiple Filter Selections
Memory Storage for 3 Calibrated Transducers
Selectable Sensor Gains
Remote Sense Excitation
Addressable for Serial Network
Tare, Peak, Valley
Unit Support: In, Cm, mm, %, Lb, Kg, N, mV/V, User Defined
TEDS-Tag® Auto Identification
Power Supplies Internally Isolated

Graphical User Interfaces (GUI) and Software Drivers sold separately. Select from:
CellView Lite GUI (Cat. No. 514569)
CellView Multi-Display GUI (Cat. No. 514424)
CellView with Graphing GUI (Cat. No. 514358)
Software Drivers (Cat. No. 514864)

CellMite® 4338-200 Specifications:

Excitation:
Voltage: 3kHz, 3Vrms (std)
Sensors: LVDT's AC Bridges

Operation:
Internal Resolution: 24-bit
Input Range: Software adjustable from 10mV/V to 100mV/V

Conversion Rate:
60 per second single channel only
7.5/sec dual channel
Error: 0.05%, +/-1 count.
Precision Shunt: 60K Ohms for bridge applications.
Pushbuttons: Tare, Shunt
Indicator: Status LED

Outputs:
Analog: 16-bit, Scalable, +/-10V.
Serial Data: Multidrop RS232, RS485
Switch: Dual Solid State Relays

Power:
Included Adapter: 5 VDC, 0.6 A (std), 110/240VAC, 60/50 Hz.
Optional Adapter: 12, 24, 48 VDC

Mechanical:
Size: 6" x 2.75" x 1.2"
Weight: 8.2 oz. (235 g)