Click to Share
 

ETCO2+SPO2 Patient Monitor 3.5 Inch

RSD2001A is a Portable Patient Monitor that has abundant monitoring functions and is used for the clinical monitoring of adult, pediatric and neonate.

Manufacturer - ronseda electronic sco.,ltd
Model # - RSD2001A
SKU - RSD2001A
Submitted By - ronseda electronics co.,ltd (Manufacturer, Manufacturer)
Country - China
Category - Medical Equipment : ULTRASOUND SCANNER : Patient Monitor

Contact   |   Link To Product   |   More Products By This Company

Specifications

size :   3.5"
resolution :   256X120
Weight :   5.5 kg
Device :   5 digital LED windows

Details

RSD2001A is a Portable Patient Monitor that has abundant monitoring functions and is used for the clinical monitoring of adult, pediatric and neonate. In addition, the user may select the different parameter configuration according to different requirements.

RSD2001A (standard)can monitor vital signals correlating to SpO2 and CO2. It integrates parameter measuring modules and display in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient. The LCD of high resolution and bright LED display provides clear view of 2 waveforms,SPO2,PR,EtCO2,InCO2,Respiration rate.

Specifications
Display
Messages:
2 Waveforms
2 indicator lights
2 Sound Mode corresponding Alarm Mode
Device:
1 dot matrix LCD size: 3.5", resolution: 256X120
5 digital LED windows

CO2
Method Infra-red Absorption Technique
Measuring mode Sidestream
Side-stream mode sampling gas flow rate
100, 150, 200 ml/Min (option)
Measuring range
CO2 0~99 mmHg
INSCO2 0-99 mmHg
AwRR 0~150 rpm
Resolution
CO2 1 mmHg
INSCO2 1mmHg
AwRR 1 rpm
Accuracy
CO2
2 mmHg,0 ~ 40 mmHg
5% of reading,41 ~ 76 mmHg
10% of reading, 77 ~ 99 mmHg
AwRR 2 rpm
Actualization interval about 1 Sec.
Start-up Time: < 10 sec
Rise Time: 240 msec (10% to 90 %)
Delay Time: 1.12 seconds maximum with 7| length, 0.055|| ID.
Sampling line at 175 ml/min
Alarm range
CO2 0 ~ 99 mmHg
InsCO2 0 ~ 99 mmHg
AwRR 0 ~ 150 rpm
Suffocation Alarm Delay
AwRR 10 ~ 40 Sec

SpO2
Measuring Range 0 ~ 100 %
Alarm Range 0 ~ 100 %
Resolution 1 %
Accuracy 70% ~ 100% 2 %
0% ~ 69% unspecified
Actualization interval about 1Sec
Alarm Delay 10 Sec.
Pulse Rate
Measuring and Alarm Range
0~254bpm
Resolution 1bpm
Accuracy 2bpm
Alarm Delay 10 Sec.

Recall
Trend Recall
8 to 96hours all parameters result.
NIBP Measurement Recall
50 NIBP measurement data.

Signal Interface
Amplitude 1 V/mV
Accuracy < 5 %
Impedance 50
Signal Delay < 20 mS

Battery
Rechargeable 4.0 A/Hr 8.4V Li-ion battery
Operating time under the normal use and full charge greater than 4 hours
Operating time after the first alarm of low battery will be about 5 minutes
Maximum charging time is 4 hours

Environment
Temperature
Working 0 ~ 40 degrees
Transport and Storage -20 ~ 60 degrees
Humidity
Working 30% - 85 %
Transport and Storage 30% - 93 %(no coagulate)
Altitude
Working -500 to 4,600m
Transport and Storage -500 to 13,100m

Power Supply
100/250 VAC, 50/60 Hz (for adapter)
Pmax=30VA
Dissipation
Working Less than 3W
Power-off Less than 0.1W

Size and Weight
Size 318 x 152 x 264 mm
Weight 5.5 kg

Accessories
Standard:
Model number: RSD 2001A SPO2+ETCO2
1 main unit
1 SPO2 cable
10 ETCO2 tube
1 user manual

Optional:
Model number: RSD 2001B SPO2+NIBP
Model number: RSD 2001C ETCO2
Model number: RSD 2001D SPO2
Model number: RSD 2001E SPO2+NIBP+ETCO2
Printer

Tags

,


Disclaimer: Submitters of product listings are solely responsible for their content. PRLog can't be held liable for the contents of the product listings.   Report Abuse


Like PRLog?
9K2K1K
Click to Share