4-20ma to RS485/232 converters

ISO40xx series realizes sensor-to-host signal acquisition for testing analog signal or remote applications. Software-configurable for a wide variety of sensor types, including: analog input, analog output, and digital I/O.

Manufacturer - Shenzhen SUNYUAN Technology Co.,Ltd.
Model # - ISO4011/ISOADA08/ISO4014
Submitted By - Shenzhen SUNYUAN Technology Co.,Ltd. (Manufacturer)
Country - China
Category - Entertainment

Contact   |   Link To Product   |   More Products By This Company

Specifications

size :   116.5x101x23mm
name :   4-20ma to RS485
input :   Multirange
input signal :   thermocouple input
input signa :   current signals input

Details

>>Single-channel analog signal-conditioning modules,isolated RS-485/232 output
>>Testing accuracy>0.05%
>>Can be remotely reconfigured for modules accuracy and input ranges
>>Three-port isolation(input/output/assistant power supply): 3000VDC
>>Power supply:24VDC/15VDC/12VDC/5VDC
>>High reliability,easy programme,installation.
>>Temperature sensors for offsetting thermocouple cold port
>>J/ K/ T/ E/ R/ S/ B thermocouple input
>> ±15 mV/ ±50 mV/ ±100 mV/ ±500 mV millivolt small signal input
>> ±1 V / ±2.5 V voltage signals or ±20 mA current signals input
Applications
>>Temperature signal testing/monitoring/cintrol
>>RS-232/485 industrial automation control system
>>Industial field signal isolation
>>Process Monitoring & Control
>>Test sensors signal
>>Laboratory Data Acquisition
>>Medical machine monitoring
>>4-20mA/0-20mA signal acquisition
ISO 4011 Function Description
ISO 4011 is single-channel isolated signal-conditioning modules. Accepts outputs from Thermocouple, millivolt, volt and current signals.
Anaolg Input Module:
24-bit accuracy,have been calibrated all signal input before ex-factor.Also,Users can programme himself when modules working.Thermocouple input break line testing,linearity compensation and cold port temperature compensation.
Communication software:
Communication Interface: Module has one standard RS-485 interface
Communication agreement: Standard ASCII, MODBUS,can make network communicate with PLC,RTU or watch software.
Data format: 10-bit,1 start bit, 8 data bits, 1 stop bit, no parity. (N, 8, 1)
Communication address (0~255) and baud rate (300、600、1200、2400、4800、9600、19200、38400bps),Max. communication distance: 1200m,connect by both twists shiled cable.±15KV ESDprotection,communication response time is less than 70mS.
(2-wire) Alarm signaling output:
When choose products with alarm function,output two channels switching alarm signal,they are used to high&low control and alarm.
Anti-jamming:
Set checksum according to need.Its inside contains MOMENTARY bate diode.