Click to Share
 

Filter Products

Clear All Filters

List All By This Company
Category
More
Dead Band

Approximately 2% (3)


Manufacturer

Time Mark Corporation (23)


Mounting

Surface (3)


Repeat Accuracy

± 0.1% of set point (fixed conditions) (3)


Response Time

50 msec (set or reset) (3)


Supply Voltage

12, 24, 120 or 230 VAC/DC (3)


Products > Time Mark Corporation

1 - 24 new products new products

Model 403 - Liquid Level Controller www.Time-Mark.com
United States - Industrial - Industrial Controls - Pump Controllers, 13 years ago, 1149 hits
The 403 Liquid Level Controller provides central control of duplex pumping systems. The Model 403 includes pump alternating, visual run-time meters, hand-off-auto control and alarm outputs.

Model 650 Loop Power Supply www.Time-Mark.com
United States - Industrial - Industrial Controls - Special Controls, 14 years ago, 625 hits
The Model 650 Loop Power Supply provides DC power for instrumentation control modules.

Model 98A498 Enclosure www.Time-Mark.com
United States - Industrial - Industrial Controls - Accessories, 14 years ago, 801 hits
The 98A498 Safety Enclosure is designed to provide external protection to Time Mark’s socket-mounted devices. The enclosure is made of 20-gauge steel with a gray finish. A standard 8-pin socket is pre-mounted inside the enclosure.

Model 421 Motor Load Monitor www.Time-Mark.com
United States - Industrial - Industrial Controls - Motor Controls, 14 years ago, 673 hits
The Model 421 detects an overload or under-load condition on all types of running motors; conveyors, elevator motors, mixer motors, submersible pumps, suction pumps, etc. The monitor detects the actual power used and is more simple than others.

Model 158 3-Phase Monitor www.Time-Mark.com
United States - Industrial - Industrial Controls - 3-Phase Monitors, 14 years ago, 760 hits
The Model 158 continuously monitors 3-phase power lines for abnormal conditions. When properly adjusted, the Model 158 monitor will detect phase loss on a loaded motor even when regenerated voltage is present.

Model 2601 Under Voltage Monitor www.Time-Mark.com
United States - Industrial - Industrial Controls - Voltage Monitors, 14 years ago, 626 hits
The Model 2601 is a single-set-point under-voltage monitor. Input voltages above set-point will cause the output contact to energize and LED indicator to illuminate. Input voltages below the set-point cause output contact to de-energize.

Model 252 3-Phase Monitor www.Time-Mark.com
United States - Industrial - Industrial Controls - 3-Phase Monitors, 14 years ago, 753 hits
The Model 252 3-Phase Monitor continuously monitors 3-phase power lines for abnormal conditions. When properly adjusted, the Model 252 will detect phase loss on a loaded motor even when regenerated voltage is present.

Model 4052 Pump-Down Controller www.Time-Mark.com
United States - Industrial - Industrial Controls - Pump Controllers, 14 years ago, 1003 hits
The Model 4052 Pump-Down Controller provides total control for duplex pumping systems. The Model 4052 monitors, controls and displays the liquid level in a tank or reservoir, up to a depth of 34.6 feet.

Model 269 Over/Under 3-Phase Monitor www.Time-Mark.com
United States - Industrial - Industrial Controls - 3-Phase Monitors, 14 years ago, 824 hits
The Model 269 Over and Under 3-Phase Monitor continuously monitors 3-phase lines for high voltage, low voltage, phase loss or phase reversal. This device features a solidstate voltage and phase-angle sensing circuit, which drives a SPDT output relay.

Model 259 3-Phase Monitor www.Time-Mark.com
United States - Industrial - Industrial Controls - 3-Phase Monitors, 14 years ago, 747 hits
The Model 259 3-Phase Monitor is designed to protect individual 3-phase equipment and motors, or in conjunction with shunt trip breakers. When correct voltage and phase rotation is applied, an internal DPDT relay energizes.

Model 295 Capacitor Trip Device - www.Time-Mark.com
United States - Industrial - Industrial Controls - Trip Devices, 14 years ago, 881 hits
The Model 295 Capacitor Trip Device is used to trip circuit breakers requiring an AC voltage, by using the stored energy in a capacitor. The capacitor is kept at full charge during normal operation by a half-wave silicon rectifier.

Model 260 Voltage Sensor - www.Time-Mark.com
United States - Industrial - Industrial Controls - Voltage Monitors, 14 years ago, 771 hits
The Model 260 is a single set-point voltage sensor. Input voltages above the set-point cause the output contacts to energize (contacts 1 & 8 closed). Input voltages below the set-point cause the output contacts to de-energize(contacts 1 & 2closed).

Model 2652 3-Phase Monitor www.Time-Mark.com
United States - Industrial - Industrial Controls - 3-Phase Monitors, 14 years ago, 763 hits
The Model 2652 3-Phase Monitor is designed to protect motors, pumps, HVAC equipment, air compressors, etc., by sensing phase loss, low voltage or phase reversal.

Model 263 - 3-Phase Monitor www.Time-Mark.com
United States - Industrial - Industrial Controls - 3-Phase Monitors, 14 years ago, 734 hits
The Model 263 continuously monitors 3-phase power systems for phase loss, low voltage and phase reversal. The monitor consists of a solid-state sensing circuit, driving an electromechanical relay.

Models 338/368 Recycle Timers www.Time-Mark.com
United States - Industrial - Industrial Controls - Time Delay Relays, 14 years ago, 776 hits
The Models 338 and 368 Recycle Timers are designed to cycle a load on and off, or to cycle between two loads. The ON and OFF cycles are independently adjustable on each model. Solid-state circuits in each drive an internal electromechanical relay.

Models 2500/2501 3-Phase Monitor www.Time-Mark.com
United States - Industrial - Industrial Controls - 3-Phase Monitors, 14 years ago, 644 hits
The Model 2500 3-Phase Monitor is designed to continuously monitor 3-phase power lines for abnormal conditions. This device features solid-state voltage and phase-angle sensing circuits, which drive a SPDT electromechanical output relay.

Models 330/360 Operate Delay Relays www.Time-Mark.com
United States - Industrial - Industrial Controls - Time Delay Relays, 14 years ago, 715 hits
The Model 330 and Model 360 Operate Delay Relays are designed for a wide range of industrial applications. Examples include automatic and machine tool control circuits, HVAC circuits, and warm-up delay circuits.

Model 261 Series Alternating Relays www.Time-Mark.com
United States - Industrial - Industrial Controls - Alternating Relays, 14 years ago, 965 hits
The Model 261 series Alternating Relay is designed for duplex pumping systems where it is desirable to equalize pump run time.

Model 257 - 3-Phase Monitor www.Time-Mark.com
United States - Industrial - Industrial Controls - 3-Phase Monitors, 14 years ago, 744 hits
The Model 257 continuously monitors 3-phase power lines for abnormal conditions. When properly adjusted, the Model 257 monitor will detect phase loss on a loaded motor even when regenerated voltage is present.

Model 2644 3-Phase Monitor www.time-mark.com
United States - Industrial - Industrial Controls - 3-Phase Monitors, 14 years ago, 743 hits
The Model 2644 3-Phase Monitor continuously monitors 3-phase Wye or Delta systems for abnormal conditions.

Models 331 and 361 Release Delay Relays www.time-mark.com
United States - Industrial - Industrial Controls - Time Delay Relays, 14 years ago, 793 hits
The Models 331 and 361 Release Delay Relays are designed for a wide usage in new or replacement industrial applications. Ex: include delay-off circuits, batch processing circuits, and other applications requiring a remote-triggered, off-delay timer.

Model 2611 Alternating Controller www.time-mark.com
United States - Industrial - Industrial Controls - Alternating Relays, 14 years ago, 619 hits
Model 2611 Alternating Controllers are microprocessor-based designs for use where two loads are required to alternate for equal run time.

Model 258 - 3 Phase Monitors www.time-mark.com
United States - Industrial Controls - 3 Phase Monitors, 14 years ago, 789 hits
The Model 258 continuously monitors 3-phase power lines for abnormal conditions. When properly adjusted, the Model 258 monitor will detect phase loss on a loaded motor even when regenerated voltage is present.

Model 2002Y Wye Voltage Unbalance Monitor www.time-mark.com
United States - Industrial - Industrial Controls, 14 years ago, 797 hits
The Model 2002Y 3-Phase Voltage Unbalance Monitor is designed to continuously monitor a three-phase line with a neutral connection for unbalanced voltage conditions.



Like PRLog?